Description
GECKO 4TX
4x FE TX, 12-24 V DC, 0-60°C, Lite Managed
Lite Managed Industrial ETHERNET Rail-Switch, Ethernet/Fast-Ethernet Switch, Store and Forward Switching Mode, fanless design.
Product description
Type | GECKO 4TX |
---|---|
Description | Lite Managed Industrial ETHERNET Rail-Switch, Ethernet/Fast-Ethernet Switch, Store and Forward Switching Mode, fanless design. |
Port type and quantity | 4 x 10/100BASE-TX, TP-cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity |
More Interfaces
Power supply/signaling contact | 1 x plug-in terminal block, 3-pin, no signaling contact |
---|
Network size – length of cable
Twisted pair (TP) | 0-100 m |
---|
Network size – cascadibility
Line – / star topology | any |
---|
Power requirements
Current consumption at 24 V DC | 120 mA |
---|---|
Operating Voltage | 9.6 V – 32 V DC |
Power consumption | 2.35 W |
Power output in BTU (IT)/h | 8.0 |
Software
Switching | TOS/DSCP prioritization (Mapping TOS/DSCP to 802.1D/p), Prioritization through 4 queues, Static unicast/multicast filter entries (up to 100), VLAN Support |
---|---|
Redundancy | RSTP (IEEE 802.1D-2004) |
Management | Web-interface, HTTP(s) config file/firmware transfer, SNMP v1/v2/v3 |
Diagnostics | Device status indication (LEDs), Log-File, RMON (1) statistics, Simple interface statistics, Topology Discovery according to IEEE 802.1AB (LLDP) |
Configuration | DHCP Relay with Option 82, HiDiscovery, BOOTP/DHCP |
Security | SNMPv3 (authNoPriv), Possibility to disable each port |
Ambient conditions
MTBF (MIL-HDBK 217F: Gb 25 ºC) | 56.6 Years |
---|---|
Operating temperature | 0-+60 °C |
Storage/transport temperature | -40-+85 °C |
Relative humidity (non-condensing) | 5-95 % |
Dimensions (WxHxD) | 25 mm x 114 mm x 79 mm |
Weight | 103 g |
Mounting | DIN Rail |
Protection class | IP30 |
Mechanical stability
IEC 60068-2-6 vibration | 3.5 mm, 5–8.4 Hz, 10 cycles, 1 octave/min; 1 g, 8.4–150 Hz, 10 cycles, 1 octave/min |
---|---|
IEC 60068-2-27 shock | 15 g, 11 ms duration |
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD) | 4 kV contact discharge, 8 kV air discharge |
---|---|
EN 61000-4-3 electromagnetic field | 10 V/m (80-3000 MHz) |
EN 61000-4-4 fast transients (burst) | 2 kV power line, 4 kV data line |
EN 61000-4-5 surge voltage | power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line |
EN 61000-4-6 Conducted Immunity | 10 V (150 kHz-80 MHz) |
EMC emitted immunity
EN 55032 | EN 55032 Class A |
---|---|
FCC CFR47 Part 15 | FCC 47CFR Part 15, Class A |
Approvals
Safety of industrial control equipment | cUL 61010-1 |
---|
Reliability
Guarantee | 60 months (please refer to the terms of guarantee for detailed information) |
---|
Scope of delivery and accessories
Accessories to Order Separately | Rail power supply RPS 30, RPS 80 EEC or RPS 120 EEC (CC), Mounting Accessories |
---|---|
Scope of delivery | Device, 3-pin terminal block for the supply voltage and the grounding, Safety and general information sheet |
Further Instructions
Product Documentation | https://www.doc.hirschmann.com |
---|---|
Certificates | https://www.doc.hirschmann.com/certificates.html |
History
Update and Revision | Revision Number: 0.37 Revision Date: 10-24-2023 |
---|