BELDEN – GECKO 4TX

Description

GECKO 4TX

4x FE TX, 12-24 V DC, 0-60°C, Lite Managed

Lite Managed Industrial ETHERNET Rail-Switch, Ethernet/Fast-Ethernet Switch, Store and Forward Switching Mode, fanless design.

 

Product description

Type GECKO 4TX
Description Lite Managed Industrial ETHERNET Rail-Switch, Ethernet/Fast-Ethernet Switch, Store and Forward Switching Mode, fanless design.
Port type and quantity 4 x 10/100BASE-TX, TP-cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity
More Interfaces
Power supply/signaling contact 1 x plug-in terminal block, 3-pin, no signaling contact
Network size – length of cable
Twisted pair (TP) 0-100 m
Network size – cascadibility
Line – / star topology any
Power requirements
Current consumption at 24 V DC 120 mA
Operating Voltage 9.6 V – 32 V DC
Power consumption 2.35 W
Power output in BTU (IT)/h 8.0
Software
Switching TOS/DSCP prioritization (Mapping TOS/DSCP to 802.1D/p), Prioritization through 4 queues, Static unicast/multicast filter entries (up to 100), VLAN Support
Redundancy RSTP (IEEE 802.1D-2004)
Management Web-interface, HTTP(s) config file/firmware transfer, SNMP v1/v2/v3
Diagnostics Device status indication (LEDs), Log-File, RMON (1) statistics, Simple interface statistics, Topology Discovery according to IEEE 802.1AB (LLDP)
Configuration DHCP Relay with Option 82, HiDiscovery, BOOTP/DHCP
Security SNMPv3 (authNoPriv), Possibility to disable each port
Ambient conditions
MTBF (MIL-HDBK 217F: Gb 25 ºC) 56.6 Years
Operating temperature 0-+60 °C
Storage/transport temperature -40-+85 °C
Relative humidity (non-condensing) 5-95 %
Dimensions (WxHxD) 25 mm x 114 mm x 79 mm
Weight 103 g
Mounting DIN Rail
Protection class IP30
Mechanical stability
IEC 60068-2-6 vibration 3.5 mm, 5–8.4 Hz, 10 cycles, 1 octave/min; 1 g, 8.4–150 Hz, 10 cycles, 1 octave/min
IEC 60068-2-27 shock 15 g, 11 ms duration
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD) 4 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field 10 V/m (80-3000 MHz)
EN 61000-4-4 fast transients (burst) 2 kV power line, 4 kV data line
EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
EN 61000-4-6 Conducted Immunity 10 V (150 kHz-80 MHz)
EMC emitted immunity
EN 55032 EN 55032 Class A
FCC CFR47 Part 15 FCC 47CFR Part 15, Class A
Approvals
Safety of industrial control equipment cUL 61010-1
Reliability
Guarantee 60 months (please refer to the terms of guarantee for detailed information)
Scope of delivery and accessories
Accessories to Order Separately Rail power supply RPS 30, RPS 80 EEC or RPS 120 EEC (CC), Mounting Accessories
Scope of delivery Device, 3-pin terminal block for the supply voltage and the grounding, Safety and general information sheet
Further Instructions
Product Documentation https://www.doc.hirschmann.com
Certificates https://www.doc.hirschmann.com/certificates.html
History
Update and Revision Revision Number: 0.37 Revision Date: 10-24-2023